8040W Ulta-filtration Membrane Modules for Purified Water Treatment with Pore Size 0.05um PVDF material
1. Brief Introduction
Ultrafiltration membrane has the characteristics of strong pollution resistance, high membrane filament strength and high filtration accuracy. Canpure internal pressure ultrafiltration membrane can effectively reduce the turbidity of raw water, remove suspended matter, colloids, microorganisms and other substances in the water, have strong adaptability to changes in raw water quality, simple operation and maintenance, and stable and reliable water quality.
Permanent hydrophilic
Ultrafiltration membrane is made of PVDF material crosslinked with hydrophilic components. The deepening and fixing of the hydrophilic groups makes the hydrophilicity of the membrane filaments permanently retained, the water production flux is more stable, and the pollution resistance and cleaning recovery of the membrane are significantly improved.
High intensity and large flux
Unique membrane wire cross-section structure
Thicker film wire inner diameter
Description of CNKHONG ultrafiltration modules
Module Features
The CNKHONG Ultrafiltration modules are made of high strength hollow fiber membranes, they are made of Polyvinylidene Fluoride(PVDF). The pore size of 0.03 µm is enough for the removal of bacteria, viruses, and particles including all kinds of colloids. v
The membranes have been special treated to be hydrophilic. It is easy cleaning and wettability that help maintain long term performance. v Out to In flow configuration can endure high tolerance of feed solids. They also can be used pressed air to help the cleaning recovery.
The dead-end filtration way offer higher recovery rate and energy savings. The largest water recovering rate can be more can 95%.
2.2 Structure and Specifications of UF Membrane Modules
2.2.1 Small size of UF modules
Size and weight
|
Model | KH-UF-4040W-PVDF | KH-UF-6040W-PVDF |
Module Diameter ( A, mm) | Φ90 mm | Φ160 mm | |
Module Length ( B, mm) | 960mm | 960mm | |
Module Length (C, mm) | 1106 mm | 1304 mm | |
Size of Inlet/Outlet (D, mm) | DN25 | DN32 | |
Operating Type | Outside to Inside | Outside to Inside | |
Membrane Area | 8.0 m2 | 20 m2 | |
Dry weight of the module | 5 Kg | 12 Kg | |
Parameters |
Shell material | UPVC | UPVC |
Membrane Material | PVDF | PVDF | |
Membrane pore size | 0.03μm | 0.03μm | |
Inner diameter of the hollow fiber | 0.7 mm | 0.7 mm | |
Outer diameter of the hollow fiber | 1.3mm | 1.3mm | |
Turbidity of Permeating water | ≤ 0.2NTU | ≤ 0.2 NTU | |
SDI value of permeating water
|
≤ 3 | ≤ 3 | |
Flux rate of purified water (0.10MP,20℃) |
≥1000L/H | ≥3000L/H | |
Typical Process
|
Temperature Range | 5-45 ℃ | 5-45 ℃ |
PH Value Range | 2-13 | 2-13 | |
Permeating Flux rate for different Water |
40 - 80 l/m2/hr | 40 -80 l/m2/hr | |
Operating Pressure | ≤0.12 MPa | ≤0.12MPa | |
Maximum Inlet Pressure | 0.2 MPa | 0.2MPa | |
Backwashing flux rate |
1.5-2.0 times of Permeating Flux |
1.5-2.0 times of Permeating Flux |
|
Backwashing times | Once per 30-120 minutes | Once per 30-120 minutes | |
Chemical cleaning online during backwashing | Once per 7-14 days | Once per 7-14 days |
The structure as the following:2.2.2 type A of 8 inches UF module.
Size and weight
|
Model | KH-UF-8040W-PVDF | KH-UF-8060W-PVDF |
Module Diameter ( A, mm) | Φ200 mm | Φ200 mm | |
Module Length ( B, mm) | 1220 mm | 1640 mm | |
Module Length (C, mm) | 1365 mm | 1785 mm | |
Size of Inlet/Outlet | DN50 | DN50 | |
Operating Type | Outside to Inside | Outside to Inside | |
Membrane Area | 30 m2 | 45 m2 | |
Dry weight of the module | 20 Kg | 35 Kg | |
Parameters |
Shell material | UPVC | UPVC |
Membrane Material | PVDF | PVDF | |
Membrane pore size | 0.03μm | 0.03μm | |
Inner diameter of the hollow fiber | 0.7 mm | 0.7 mm | |
Outer diameter of the hollow fiber | 1.3mm | 1.3mm | |
Turbidity of Permeating water | ≤ 0.2NTU | ≤ 0.2 NTU | |
SDI value of permeating water
|
≤ 3 | ≤ 3 | |
Flux rate for of purified water (0.10MP,20℃) |
≥ 3600L/H | ≥ 5400L/H | |
Typical Process
|
Temperature Range | 5-45 ℃ | 5-45 ℃ |
PH Value Range | 2-13 | 2-13 | |
Permeating Flux rate for different Water |
40 - 80 l/m2/hr | 40 -80 l/m2/hr | |
Operating Pressure | ≤0.12 MPa | ≤0.12MPa | |
Maximum Inlet Pressure | 0.2 MPa | 0.2MPa | |
Backwashing flux rate |
1.5-2.0 times of Permeating Flux |
1.5-2.0 times of Permeating Flux |
|
Backwashing times | Once per 30-120 minutes | Once per 30-120 minutes | |
Chemical cleaning online during backwashing | Once per 7-14 days | Once per 7-14 days |
2.2.3 type B of 8 inches UF module. The structure as the following:
Size and weight
|
Model | KH-UF-SFX2860-PVDF | KH-UF-SFX2880-PVDF |
Module Diameter (OD, mm) | Φ225 mm | Φ225 mm | |
Module Length ( L1, mm) | 1500 mm | 2000 mm | |
Module Length (L2, mm) | 1630 mm | 2130 mm | |
Module Length (L3, mm) | 1820 mm | 2320 mm | |
Module Length (L , mm) | 1860 mm | 2360 mm | |
Operating Type | Outside to Inside | Outside to Inside | |
Membrane Area | 52 m2 | 77 m2 | |
Dry weight of the module | 42 Kg | 62 Kg | |
Parameters |
Shell material | UPVC | UPVC |
Membrane Material | PVDF | PVDF | |
Membrane pore size | 0.03μm | 0.03μm | |
Inner diameter of the hollow fiber | 0.7 mm | 0.7 mm | |
Outer diameter of the hollow fiber | 1.3mm | 1.3mm | |
Turbidity of Permeating water | ≤ 0.2NTU | ≤ 0.2 NTU | |
SDI value of permeating water
|
≤ 3 | ≤ 3 | |
Flux rate of purified water (0.10MP,20℃) |
≥ 6500L/H | ≥ 8000L/H | |
Typical Process
|
Temperature Range | 5-45 ℃ | 5-45 ℃ |
PH Value Range | 2-13 | 2-13 | |
Permeating Flux rate for different Water |
40 - 80 l/m2/hr | 40 -80 l/m2/hr | |
Operating Pressure | ≤0.12 MPa | ≤0.12MPa | |
Maximum Inlet Pressure | 0.2 MPa | 0.2MPa | |
Backwashing flux rate |
1.5-2.0 times of Permeating Flux |
1.5-2.0 times of Permeating Flux |
|
Backwashing times | Once per 30-120 minutes | Once per 30-120 minutes | |
Chemical cleaning online during backwashing | Once per 7-14 days | Once per 7-14 days |
The whole installation and application process of our MBR modules are described as the following photo:
Contact Us at Any Time