Send Message
Hangzhou Kaihong Membrane Technology Co., Ltd.
Mail: cnkhong@163.com TEL: 86-571-88614796
Home > Products > UF System >
52sqm UF System Membrane Pvdf UPVC
  • 52sqm UF System Membrane Pvdf UPVC
  • 52sqm UF System Membrane Pvdf UPVC

52sqm UF System Membrane Pvdf UPVC

Place of Origin China
Brand Name CNKHONG
Model Number KH-UF-8060W-PVDF
Product Details
Material:
PVDF+UPVC
Pore Size:
0.03um
ID/OD:
1.0/2.0
Membrane Area:
52m2
Water Flux:
50-80LMH
Working Temperature:
1-40C
Highlight: 

52sqm UF System

,

UF System membrane pvdf UPVC

,

8060W ultrafiltration membrane

Product Description

8040W Ulta-filtration Membrane Modules for Purified Water Treatment with Pore Size 0.05um PVDF material

 

1. Brief Introduction

 Ultrafiltration membrane has the characteristics of strong pollution resistance, high membrane filament strength and high filtration accuracy. Canpure internal pressure ultrafiltration membrane can effectively reduce the turbidity of raw water, remove suspended matter, colloids, microorganisms and other substances in the water, have strong adaptability to changes in raw water quality, simple operation and maintenance, and stable and reliable water quality.

Features

Permanent hydrophilic

Ultrafiltration membrane is made of PVDF material crosslinked with hydrophilic components. The deepening and fixing of the hydrophilic groups makes the hydrophilicity of the membrane filaments permanently retained, the water production flux is more stable, and the pollution resistance and cleaning recovery of the membrane are significantly improved.

High intensity and large flux

Unique membrane wire cross-section structure

Thicker film wire inner diameter

 

  Description of CNKHONG ultrafiltration modules

  Module Features

The CNKHONG Ultrafiltration modules are made of high strength hollow fiber membranes, they are made of Polyvinylidene Fluoride(PVDF). The pore size of 0.03 µm is enough for the removal of bacteria, viruses, and particles including all kinds of colloids. v

The membranes have been special treated to be hydrophilic. It is easy cleaning and wettability that help maintain long term performance. v Out to In flow configuration can endure high tolerance of feed solids. They also can be used pressed air to help the cleaning recovery.

The dead-end filtration way offer higher recovery rate and energy savings. The largest water recovering rate can be more can 95%.

 

2.2 Structure and Specifications of  UF Membrane Modules

2.2.1 Small size of UF modules

aa.png

 

 

 

Size and weight

 

Model KH-UF-4040W-PVDF KH-UF-6040W-PVDF
Module Diameter ( A, mm) Φ90 mm Φ160 mm
Module Length ( B, mm) 960mm 960mm
Module Length (C, mm) 1106 mm 1304 mm
Size of Inlet/Outlet (D, mm) DN25 DN32
Operating Type Outside to Inside Outside to Inside
Membrane Area 8.0 m2 20 m2
Dry weight of the module 5 Kg 12 Kg

 

 

 

 

 

Parameters

Shell material UPVC UPVC
Membrane Material PVDF PVDF
Membrane pore size 0.03μm 0.03μm
Inner diameter of the hollow fiber 0.7 mm 0.7 mm
Outer diameter of the hollow fiber 1.3mm 1.3mm
Turbidity of Permeating water ≤ 0.2NTU ≤ 0.2 NTU

SDI value of permeating water

 

≤ 3 ≤ 3

Flux rate of purified water

(0.10MP,20℃)

≥1000L/H ≥3000L/H

 

 

 

 

Typical Process

 

Temperature Range 5-45 ℃ 5-45 ℃
PH Value Range 2-13 2-13

Permeating Flux rate for different

Water

40 - 80 l/m2/hr 40 -80 l/m2/hr
Operating Pressure ≤0.12 MPa ≤0.12MPa
Maximum Inlet Pressure 0.2 MPa 0.2MPa
Backwashing flux rate

1.5-2.0 times of

Permeating Flux

1.5-2.0 times of

Permeating Flux

Backwashing times Once per 30-120 minutes Once per 30-120 minutes
Chemical cleaning online during backwashing Once per 7-14 days Once per 7-14 days


The structure as the following:2.2.2 type A of 8 inches UF module.

ab.png

 

 

 

Size and weight

 

Model KH-UF-8040W-PVDF KH-UF-8060W-PVDF
Module Diameter ( A, mm) Φ200 mm Φ200 mm
Module Length ( B, mm) 1220 mm 1640 mm
Module Length (C, mm) 1365 mm 1785 mm
Size of Inlet/Outlet DN50 DN50
Operating Type Outside to Inside Outside to Inside
Membrane Area 30 m2 45 m2
Dry weight of the module 20 Kg 35 Kg

 

 

 

 

 

Parameters

Shell material UPVC UPVC
Membrane Material PVDF PVDF
Membrane pore size 0.03μm 0.03μm
Inner diameter of the hollow fiber 0.7 mm 0.7 mm
Outer diameter of the hollow fiber 1.3mm 1.3mm
Turbidity of Permeating water ≤ 0.2NTU ≤ 0.2 NTU

SDI value of permeating water

 

≤ 3 ≤ 3

Flux rate for of purified water

(0.10MP,20℃)

≥ 3600L/H ≥ 5400L/H

 

 

 

 

Typical Process

 

Temperature Range 5-45 ℃ 5-45 ℃
PH Value Range 2-13 2-13

Permeating Flux rate for different

Water

40 - 80 l/m2/hr 40 -80 l/m2/hr
Operating Pressure ≤0.12 MPa ≤0.12MPa
Maximum Inlet Pressure 0.2 MPa 0.2MPa
Backwashing flux rate

1.5-2.0 times of

Permeating Flux

1.5-2.0 times of

Permeating Flux

Backwashing times Once per 30-120 minutes Once per 30-120 minutes
Chemical cleaning online during backwashing Once per 7-14 days Once per 7-14 days


2.2.3 type B of 8 inches UF module. The structure as the following:

ac.png

 

 

 

 

Size and weight

 

Model KH-UF-SFX2860-PVDF KH-UF-SFX2880-PVDF
Module Diameter (OD, mm) Φ225 mm Φ225 mm
Module Length ( L1, mm) 1500 mm 2000 mm
Module Length (L2, mm) 1630 mm 2130 mm
Module Length (L3, mm) 1820 mm 2320 mm
Module Length (L , mm) 1860 mm 2360 mm
Operating Type Outside to Inside Outside to Inside
Membrane Area 52 m2 77 m2
Dry weight of the module 42 Kg 62 Kg

 

 

 

 

 

Parameters

Shell material UPVC UPVC
Membrane Material PVDF PVDF
Membrane pore size 0.03μm 0.03μm
Inner diameter of the hollow fiber 0.7 mm 0.7 mm
Outer diameter of the hollow fiber 1.3mm 1.3mm
Turbidity of Permeating water ≤ 0.2NTU ≤ 0.2 NTU

SDI value of permeating water

 

≤ 3 ≤ 3

Flux rate of purified water

(0.10MP,20℃)

≥ 6500L/H ≥ 8000L/H

 

 

 

 

Typical Process

 

Temperature Range 5-45 ℃ 5-45 ℃
PH Value Range 2-13 2-13

Permeating Flux rate for different

Water

40 - 80 l/m2/hr 40 -80 l/m2/hr
Operating Pressure ≤0.12 MPa ≤0.12MPa
Maximum Inlet Pressure 0.2 MPa 0.2MPa
Backwashing flux rate

1.5-2.0 times of

Permeating Flux

1.5-2.0 times of

Permeating Flux

Backwashing times Once per 30-120 minutes Once per 30-120 minutes
Chemical cleaning online during backwashing Once per 7-14 days Once per 7-14 days


The whole installation and application process of our MBR modules are described as the following photo:

52sqm UF System Membrane Pvdf UPVC 3

52sqm UF System Membrane Pvdf UPVC 4

 

 

 

 

 

 

 

 

 

Contact Us at Any Time

86-571-88614796
Bldg 10-1, # 11 Lingang Rd, Renhe Street, Yuhang Dist, Hangzhou, China
Send your inquiry directly to us